3 Phase Inverter

3 Phase Inverter

  • $0.00


Contact us for pricing on 3 phase Inverters.

Three phase Inverter Feature:

Capacity: 1KW--100KW 
1) super wide input voltage: 285V-475V
2) completely controlled by CPU, LCD automatic page turning display
3) protection against output short-circuit; Against overload, and when you throw off its load, it will turn on the unit automatically. 
4)working for single phase and three phase. 
110V/220V single phase ;240v/380v/415V/440V option.
5) with charger built-in, its charging current is 10A----156A. 
6) different DC voltage:  24V, 48V, 96V, 384V for optional 
7) make it with 3 pcs PCB,it is more stable design.
8)this kinds inverter can take pump or lift,and other industrial use
9)up to 10kw ,use Efficient IGBT(Insulated Gate Bipolar Transistor)inversion technology

Specification:

MODEL T1K T3K T5K T10K T15K T20K T30K T60K T100K
Power 1KW 3KW 5KW 10KW 15KW 20KW 30KW 60KW 100KW
Power Factor 0.8
Input Phase 3 phase 4 wire and ground
Voltage Range 110V(1 phase)/208V± 20%(3phase voltage)(1-5KW)
127V(1 phase)/220V ± 20%(3phase voltage)(1-5KW)
220V(1 phase)/380V± 20% (3 phase voltage) (1-100KW)
Frequency Range 45-55HZ or 57– 65Hz
Rectifier 3 phase 6 pulses, 12 pulses is optional
Output Phase 3 phase 4 wire and ground
Wave form Pure sine wave
Crest Factor 3: 01
Rated voltage 217V/220V/380/400/415V optional
+ -1% for static load, 5% for fluctuant load
Phase voltage setting 200 - 244VAC, pls confirm when order
Transient response +/-5%, 10ms
Frequency 50 / 60 Hz + / - 0.05%
Total-harmonic distortion < 3% linear load, < 5%( nonlinear load)
Short circuit current Short current for 0.1s (200% current)
Overload capacity Overload 125% for 10 Ms, 125%-150% for 1min. automatically resume when load become normal
Battery Battery Maintenance free lead-acid cell
DC Voltage 48v or 96V(1-10KW) 192V
(15KW)
384V(20-100KW)
Max Charge Current 6-30A adjustable
Bypass Type Static state + manual maintenance bypass
Input Phase 3 phase 4 wire and ground
Input voltage range 15% - 25% (the front control panel selectable)
Transfer time Inverter / bypass transfer switch time(Overload): 0ms inverter / bypass transfer switch time (fault inverter) 1ms
Efficiency Whole unit > 85%
Inverter 91 91 92 92 93 93 95 95 95
Remote signaling Dry contact (battery low, battery discharging, bypass/ fault); output 12Vdc/80mA, Optional parts
Communication interface RS232 ( SNMP, modem optional )
Running temperature 0-40 degree Celsius
Relative Humidity Less than 95% (without condensing)
Noise at 1 M less than 60 dB
Degree of protection IP20
Applicable Standards EN50091-1-EMC EN50091-2liv. A
Product size(mm) (1kw-4kw):560*230*570mm; (5kw-15kw)590*470*730mm
(20kw-60kw)900*600*1380mm; (80kw-100kw)1200*900*1820mm
product weight(Kg) 30 40 54 104 125 190 380 690 800
Package size(mm) (1kw-4kw):640*300*730mm; (5kw-15kw):690*570*850mm
(20kw-60kw):1135*810*1430mm;(80kw-100kw):1450*1110*1880mm
Package weight(Kg) 32 50 60 123 145 215 420 750 860